(1)  Except as permitted in Sentences (2) and (3), openings through guards shall be of a size that prevents the passage of a spherical object having a diameter of 100 mm.

=

    (2)  Except where they serve storage garages, guards in industrial occupancies are permitted to consist of,

    (a)   a top railing, and

    (b)   one or more horizontal intermediate rails spaced such that the size of the openings through the guard prevents the passage of a spherical object having a diameter of 535 mm.

    (3)  Openings through any guard that is not required by Article 9.8.8.1. and that serves an occupancy other than industrial occupancy, shall be of a size that,

    (a)   prevents the passage of a spherical object having a diameter of 100 mm, or

    (b)   permits the passage of a spherical object having a diameter of 200 mm.

Article 9.8.8.5 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.