Receptacles exposed to the weather

Receptacles exposed to the weather (see Appendix B) 1) Receptacles exposed to the weather shall be provided with wet location cover plates. 2) Receptacles of CSA configurations 5-15R, 5-20R, 5-20RA, 6-15R, 6-20R, and 6-20RA shall be provided with cover plates suitable for wet locations, whether or not a plug is inserted into the receptacle, and […]
Read more

Receptacles for dwelling units (see Appendices B and G)

Receptacles for dwelling units (see Appendices B and G) Receptacles for dwelling units (including single dwellings) shall meet the following requirements: a) except as otherwise provided for in this Code, in dwelling units duplex receptacles shall be installed in the finished walls of every room or area, other than bathrooms, hallways, laundry rooms, water closet […]
Read more

Receptacles for electric vehicle supply equipment (see Appendix B)

Receptacles for electric vehicle supply equipment (see Appendix B) 1) Each receptacle for the purpose of electric vehicle charging shall be labelled in a conspicuous legible, and permanent manner, identifying it as an electric vehicle supply equipment receptacle and shall be a) a single receptacle of CSA configuration 5-20R supplied from a 125 V branch […]
Read more

Receptacles for single dwellings (see Appendices B and G)

Receptacles for single dwellings only shall meet the following requirements: a) for each single dwelling, at least one duplex receptacle shall be installed outdoors so as to bereadily accessible from ground or grade level for the use of appliances that need to be used outdoors; b) at least one duplex receptacle readily accessible from floor […]
Read more

Recessed Lighting Fixtures

Recessed Lighting Fixtures (1)  Recessed lighting fixtures shall not be located in insulated ceilings unless the fixtures are designed for such installations. Article 9.34.1.4 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Running of cable between boxes and fittings

Running of cable between boxes and fittings (see Appendices B and G) 1) Where the cable is run between boxes and fittings, it shall be supported by straps, Type 2S or 21S cable ties, or other devices located a) within 300 mm of every box or fitting; andb) at intervals of not more than 1.5 […]
Read more

Single Switch Ceiling Fan Wiring Diagram

Single Switch Ceiling Fan Wiring Diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note : The light and fan are controlled by the same switch.
Read more