Masonry Veneer

Masonry Veneer When masonry veneer is used for cladding, the foundation must include a supporting ledge or offset wide enough to allow a space at least 25 mm (1 in.) between the masonry and the sheathing membrane (Figure 113). Insulating concrete form (ICF) foundations may use a reinforced flare at the top of the foundation […]
Read more

Materials for Flashing

Materials for Flashing (1)  Materials used for flashing shall conform to Table 9.20.13.1.                (2)  Aluminum flashing in contact with masonry or concrete shall be effectively coated or separated from the masonry or concrete by an impervious membrane. Article 9.20.13.1 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Maximum Spans for Built-up Ridge Beams and Lintels Supporting

Maximum Spans for Built-up Ridge Beams and Lintels Supporting the Roof and Ceiling Only – No. 1 or No. 2 Grade Table A-12 Forming Part of Sentences 9.23.4.2.(4), 9.23.12.3.(1) and (3), 9.23.13.8.(2) and 9.37.3.1.(1) Notes to Table A-12: (1) Beam and lintel spans are calculated based on a maximum supported length of 4.9 m.  Spans may […]
Read more

Maximum Spans for Glued-Laminated Timber Lintels – 20f-E Stress Grade – Exterior Walls – Roof and Ceiling Load Only

Maximum Spans for Glued-Laminated Timber Lintels – 20f-E Stress Grade – Exterior Walls – Roof and Ceiling Load Only Table A-16 Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1) Notes to Table A-16: (1) Spans are valid for glued-laminated timber conforming to CAN/CSA-O122 and CSA O177. (2) Provide a minimum bearing length of 89 mm. (Alternatively, […]
Read more