Anchorage Cantilevered Precast Concrete Steps

Anchorage Cantilevered Precast Concrete Steps (1)  Cantilevered concrete steps referred to in Article 9.8.10.1. shall be anchored to concrete foundation walls at least 200 mm thick. Article 9.8.10.2 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Anchorage of Building Frames

Anchorage of Building Frames (1)  Building frames shall be anchored to the foundation unless a structural analysis of wind and earth pressures shows anchorage is not required.     (2)  Except as provided in Article 9.23.6.3., anchorage shall be provided by embedding the ends of the first floor joists in concrete, or fastening the sill plate to the […]
Read more

Anchorage of Building Frames

Anchorage of Building Frames (1)  Building frames shall be anchored to the foundation unless a structural analysis of wind and earth pressures shows anchorage is not required.     (2)  Except as provided in Article 9.23.6.3., anchorage shall be provided by embedding the ends of the first floor joists in concrete, or fastening the sill plate to the […]
Read more

Anchorage of Columns and Posts

Anchorage of Columns and Posts (1)  Except as provided in Sentences (2) and (3), exterior columns and posts shall be anchored to resist uplift and lateral movement.     (2)  Except as provided in Sentence (3), where columns or posts support balconies, decks, verandas and other exterior platforms, and the columns or posts extend not more than 600 […]
Read more

Anchorage of Smaller Buildings

Anchorage of Smaller Buildings (1)  Buildings not more than 4.3 m wide and not more than 1 storey in building height are permitted to be anchored in conformance with the requirements of CSA Z240.10.1, “Site Preparation, Foundation, and Installation of Buildings”. Article 9.23.6.3 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes […]
Read more

Anchorage of Smaller Buildings

Anchorage of Smaller Buildings (1)  Buildings not more than 4.3 m wide and not more than 1 storey in building height are permitted to be anchored in conformance with the requirements of CSA Z240.10.1, “Site Preparation, Foundation, and Installation of Buildings”. Article 9.23.6.3 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes […]
Read more

Application of Dampproofing Material

Application of Dampproofing Material (1)  Exterior dampproofing shall be applied from finished ground level to the top of the exterior of the footing.     (2)  Unless otherwise stated in this Subsection, dampproofing shall be installed in accordance with the manufacturer’s instructions with regard to,     (a)   surface priming,     (b)   conditions during application,     (c)   application quantity […]
Read more