Sump Pits

Sump Pits, (1)  Where gravity drainage is not practical, a covered sump with an automatic pump shall be installed to discharge the water into a sewer, drainage ditch or dry well.     (2)  Covers for sump pits shall be,     (a)   designed to resist removal by children, and     (b)   sealed in accordance with Sentence 9.25.3.3.(16). Article […]
Read more

Support of Beams

(1)  Not less than a 190 mm depth of solid masonry shall be provided beneath beams supported on masonry. (2)  Where the beam referred to in Sentence (1) is supported below the top of the foundation walls, the ends of such beams shall be protected from the weather. Article 9.15.5.2 Ontario Regulation 332/12 Building Code,   Information […]
Read more

Support of Floor Joists

Support of Floor Joists and Beams on Masonry Foundation Walls (1)  Except as permitted in Sentence (2), foundation walls of hollow masonry units supporting floor joists shall be capped with,     (a)   not less than 50 mm of concrete,     (b)   solid masonry units that are 100% solid and not less than 50 mm high, or […]
Read more

Support of Footings

Support of Footings (1)  Footings shall rest on undisturbed soil, rock or compacted granular fill.     (2)  Granular fill shall not contain pyritic material in a concentration that would adversely affect its stability or the performance of assemblies separating dissimilar environments. Article 9.15.3.2 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Surface Drainage

Surface Drainage, (1)  The building shall be located or the building site graded so that water will not accumulate at or near the building and will not adversely affect adjacent properties. Article 9.14.6.1 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Table Corrosion Resistance of Connectors

Table Corrosion Resistance of Connectors Table 9.20.16.1.Minimum Requirements for Galvanizing Forming Part of Sentence 9.20.16.1.(1) Notes to Table 9.20.16.1.: (1) ASTM A123 / A123M does not apply to metal less than 3.18 mm thick.  Galvanizing coatings may be interpolated for thicknesses between 3.18 mm and 0.76 mm. Table 9.20.16.1. Ontario Regulation 332/12 Building Code,   Information […]
Read more

Termite and Decay Protection

(1)  In localities where termites are known to occur,     (a)   clearance between structural wood elements and the finished ground level directly below them shall be not less than 450 mm and, except as provided in Sentence (2), all sides of the supporting elements shall be visible to permit inspection, or (b) structural wood elements, supported […]
Read more