Wall Studs

Wall Studs (1)  Wall studs shall not be notched, drilled or otherwise damaged so that the undamaged portion of the stud is less than two-thirds the depth of the stud if the stud is loadbearing or 40 mm if the stud is non-loadbearing, unless the weakened studs are suitably reinforced. Article 9.23.5.3. Ontario Regulation 332/12 Building […]
Read more

Wall Tile Finish Adhesives

Wall Tile Finish Adhesives (1)  Adhesives to attach ceramic and plastic tile shall be applied to the finish coat or brown coat of plaster that has been steel-trowelled to an even surface or to gypsum board or to masonry provided the masonry has an even surface. Article 9.29.10.3. Ontario Regulation 332/12 Building Code,   Information published […]
Read more

Wood Furring Fastening

Wood Furring Fastening (1)  Furring shall be fastened to the framing or to wood blocks with not less than 51 mm nails. Article 9.29.3.2 Ontario Regulation 332/12 Building Code, Information published by oncodes.ca for educational purposes only
Read more

Wood Furring Size and Spacing

Wood Furring Size and Spacing Wood furring for the attachment of wall and ceiling finishes shall conform to Table 9.29.3.1. Table 9.29.3.1.Size and Spacing of Furring Forming Part of Sentence 9.29.3.1.(1) Article and Table 9.29.3.1 Ontario Regulation 332/12 Building Code, Information published by oncodes.ca for educational purposes only
Read more

Wood Strip Flooring Thickness

Wood Strip Flooring Thickness (1)  The thickness of wood strip flooring shall conform to Table 9.30.3.1. Table 9.30.3.1.Thickness of Wood Strip Flooring Forming Part of Sentence 9.30.3.1.(1) Article 9.30.3.1 Ontario Regulation 332/12 Building Code,   O. Reg. 332/12: BUILDING CODE (ontario.ca) © Queen’s Printer for Ontario, 2021