Outlet boxes

Outlet boxes (see Appendix B) 1) A box or an equivalent device shall be installed at every point of outlet, switch, or junction of conduit, raceways, armoured cable, or non-metallic-sheathed cable. 2) Non-metallic outlet boxes shall not be used in wiring methods using metal raceways or armoured or metal-sheathed cable, except where the boxes are […]
Read more

Panel-Type Underlay Flooring

Panel-Type Underlay Flooring (1)  A panel-type underlay shall be provided under resilient flooring, parquet flooring, ceramic tile, felted-synthetic-fibre floor coverings or carpeting laid over lumber subflooring. (2)  A panel-type underlay shall be provided under resilient flooring, parquet flooring, felted-synthetic-fibre floor coverings or carpeting on panel-type subflooring whose edges are unsupported. (3)  Panel-type underlay shall be provided under ceramic […]
Read more

Protection for cable in concealed installations

Protection for cable in concealed installations (see Appendices B and G) 1) Where the cable is run through studs, joists, or similar members, the outer surfaces of the cable shall be kept a distance of at least 32 mm from the edges of the members, or the cable shall be protected from mechanical damage by […]
Read more

Receptacles (plugs) General

Receptacles (plugs) General (see Appendix B) 1) Receptacle configurations shall be in accordance with Diagrams 1 and 2, except a) for receptacles used on equipment solely for interconnection purposes;b) for receptacles for specific applications as required by other Rules of this Code; orc) where other configurations are suitable. 2) Except as provided for by other […]
Read more

Receptacles for dwelling units (see Appendices B and G)

Receptacles for dwelling units (see Appendices B and G) Receptacles for dwelling units (including single dwellings) shall meet the following requirements: a) except as otherwise provided for in this Code, in dwelling units duplex receptacles shall be installed in the finished walls of every room or area, other than bathrooms, hallways, laundry rooms, water closet […]
Read more

Required Barrier to Air Leakage

Required Barrier to Air Leakage (1)  Wall, ceiling and floor assemblies that separate conditioned spaces from unconditioned spaces or from the ground shall be constructed so as to include an air barrier system that will provide a continuous barrier to air leakage,     (a)   from the interior of the building into wall, floor, attic or roof […]
Read more

Required Barrier to Vapour Diffusion

(1)  Thermally insulated wall, ceiling and floor assemblies shall be constructed with a vapour barrier sufficient to prevent condensation in the wall spaces, floor spaces or attic or roof spaces. Article 9.25.4.1 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only. A vapour Barrier is required for insulation installed between the […]