Mechanical Protection for Electrical Cables

Mechanical Protection for Electrical Cables 1) Where subject to mechanical damage, mineral-insulated cable, aluminum-sheathed cable, and copper-sheathed cable shall be suitably protected. 2) Where mineral-insulated cable, aluminum-sheathed cable, or copper-sheathed cable is installed on the face of a wall, partition, ceiling, or structural member within 1.5 m of the floor, and in all locations where […]
Read more

Method of Measurement

Method of Measurement (1)  Except as otherwise specified in this Part, the areas, dimensions and heights of rooms or spaces shall be measured between finished wall surfaces and between finished floor and ceiling surfaces. Article 9.5.1.2 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Minor Combustible Components

(1)  The following minor combustible components are permitted in a building required to be of noncombustible construction:     (a)   paint,     (b)   self-adhesive tapes, mastics and caulking materials applied to provide flexible seals between the major components of exterior wall construction,     (c)   fire stops conforming to Sentence 3.1.9.1.(1) and fire blocks conforming to Article 3.1.11.7., […]
Read more

Moisture, Air Leakage, Vapour Diffusion and Heat Transfer Control

Moisture, Air Leakage, Vapour Diffusion and Heat Transfer Control In modern wood-frame houses, continuous insulation is needed to provide energy efficiency and comfort. A continuous air barrier system will restrict air movement into and out of a house, help provide thermal comfort, reduce heat loss and avoid moisture condensation in the walls and ceilings that […]
Read more

Nails for Fastening Gypsum Board

Nails for Fastening Gypsum Board (1)  Nails for fastening gypsum board to wood supports shall conform to,     (a)   ASTM F1667, “Driven Fasteners: Nails, Spikes and Staples”, or     (b)   CSA B111, “Wire Nails, Spikes and Staples”. Article 9.29.5.6. Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only. Nail Attachment Gypsum […]
Read more

Natural Ventilation Area

(1)  The unobstructed openable ventilation area to the outdoors for rooms and spaces in a residential occupancy ventilated by natural means shall conform to Table 9.32.2.1. (2)  Where a vestibule opens directly off a living or dining room within a dwelling unit, ventilation to the outdoors for such rooms may be through the vestibule Article 9.32.2.1 Ontario […]