Basic light switch wiring diagram

Basic light switch wiring diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note : Rule 4-022, Installation of identified conductor, to install the identified conductor at each control location of permanently installed luminaire that also includes manual control devices (switches). […]
Read more

Bonding of receptacles (see Appendix B)

Bonding of receptacles (see Appendix B) 1) Where grounding-type receptacles are used in existing installations to replace the ungrounded type, the grounding terminal shall be effectively bonded to ground and one of the following methods shall be permitted to be used: a) connection to a metal raceway or cable sheath that is bonded to ground;b) […]
Read more

Built-up Wood Beams

Built-up Wood Beams (1)  Where a beam is made up of individual pieces of lumber that are nailed together, the individual members shall be 38 mm or greater in thickness and installed on edge.     (2)  Except as permitted in Sentence (3), where individual members of a built-up beam are butted together to form a joint, the […]
Read more

Ceiling Fan with Switch and Light Dimmer diagram

Ceiling Fan with Switch and Light Dimmer diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note : The fan is controlled by a switch with normal on/off operation and the light by a dimmer.
Read more

Ceiling Heights of Rooms or Spaces

(1)  The ceiling heights of rooms or spaces in residential occupancies and live/work units shall conform to Table 9.5.3.1. (2)  Areas in rooms or spaces over which ceiling height is not less than the minimum specified in Table 9.5.3.1. shall be contiguous with the entry or entries to those rooms or spaces. Article 9.5.3.1 Ontario Regulation 332/12 […]
Read more

Ceiling Heights of Rooms or Spaces – Table

Table 9.5.3.1.Room Ceiling Heights Forming Part of Sentences 9.5.3.1.(1) and (2) Notes to Table 9.5.3.1.: (1) Area of the space shall be measured at floor level. Table 9.5.3.1 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Clearance to Combustible Framing

(1)  Not less than a 100 mm clearance shall be provided between the back and sides of a solid fuel-burning fireplace and combustible framing, except that a 50 mm clearance is permitted where the fireplace is located in an exterior wall.                 (2)  Not less than a 50 mm clearance shall be provided between the back […]
Read more