Joints Offset Panel-Type Underlay

Joints Offset Panel-Type Underlay (1)  Where panel-type underlay is required to be installed over plywood, or OSB or waferboard, the joints in the underlay shall be offset at least 200 mm from the joints in the underlying subfloor. Article 9.30.2.4 Ontario Regulation 332/12 Building Code,   O. Reg. 332/12: BUILDING CODE (ontario.ca) © Queen’s Printer for […]
Read more

Leading Edges of Treads

(1)  Leading edges of treads that are bevelled or rounded shall,     (a)   not reduce the required tread depth by more than 15 mm, and     (b)   not, in any case, exceed 25 mm horizontally. Article 9.8.4.6 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Length of Fasteners for Gypsum Board

Length of Fasteners for Gypsum Board (1)  The length of fasteners for gypsum board shall conform to Table 9.29.5.5., except that lesser depths of penetration are permitted for assemblies required to have a fire-resistance rating provided it can be shown, on the basis of fire tests, that such depths are adequate for the required rating. Table […]
Read more

Length of Fasteners Gypsum Board

Length of Fasteners Gypsum Board (1)  The length of fasteners for gypsum board shall conform to Table 9.29.5.5., except that lesser depths of penetration are permitted for assemblies required to have a fire-resistance rating provided it can be shown, on the basis of fire tests, that such depths are adequate for the required rating. Article 9.29.5.5. […]
Read more

Light switch with multiple lights wiring diagram

Light switch with multiple lights wiring diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note : Rule 4-022, Installation of identified conductor, to install the identified conductor at each control location of permanently installed luminaire that also includes manual control devices […]
Read more

Light switches with multiple circuits

Light switches with multiple circuits Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com
Read more

Lighting Outlets in Houses and Dwelling Units

Lighting Outlets in Houses and Dwelling Units (1)  Except as provided in Sentence (2), a lighting outlet with fixture controlled by a wall switch shall be provided in kitchens, bedrooms, living rooms, utility rooms, laundry rooms, dining rooms, bathrooms, water closet rooms, vestibules and hallways in a house or an individual dwelling unit. (2)  Where a receptacle […]
Read more