Length of Fasteners for Gypsum Board

Length of Fasteners for Gypsum Board (1)  The length of fasteners for gypsum board shall conform to Table 9.29.5.5., except that lesser depths of penetration are permitted for assemblies required to have a fire-resistance rating provided it can be shown, on the basis of fire tests, that such depths are adequate for the required rating. Table […]
Read more

Length of Fasteners Gypsum Board

Length of Fasteners Gypsum Board (1)  The length of fasteners for gypsum board shall conform to Table 9.29.5.5., except that lesser depths of penetration are permitted for assemblies required to have a fire-resistance rating provided it can be shown, on the basis of fire tests, that such depths are adequate for the required rating. Article 9.29.5.5. […]
Read more

Light switch with multiple lights wiring diagram

Light switch with multiple lights wiring diagram Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com Note : Rule 4-022, Installation of identified conductor, to install the identified conductor at each control location of permanently installed luminaire that also includes manual control devices […]
Read more

Light switches with multiple circuits

Light switches with multiple circuits Oncodes.ca publishes this information for educational purposes only. Please consult your electrician prior to any work and/or have an inspection performed. buildmyowncabin.com
Read more

Loads on Guards

Loads on Guards (1)  Except as provided in Sentences (2), (4) and (5), guards shall be designed to resist the specified loads prescribed in Table 9.8.8.2. (2)  For guards within dwelling units and in exterior guards serving not more than 2 dwelling units, where the width and spacing of pickets are such that three pickets can be […]
Read more

Loads on Guards Table

Table 9.8.8.2.Specified Loads for Guards Forming Part of Sentence 9.8.8.2.(1) Notes to Table 9.8.8.2.: (1) The load that creates the most critical condition shall apply. (2) See Sentence (2). Table 9.8.8.2 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.
Read more

Loads on Stairs and Ramps

Loads on Stairs and Ramps (1)  Except as required in Articles 9.8.9.4. and 9.8.9.5., stairs and ramps shall be designed for strength and rigidity under uniform loading criteria to support specified loads of,     (a)   1.9 kPa for stairs and ramps serving a house or an individual dwelling unit, and     (b)   4.8 kPa for other […]
Read more