Water Closet Screws, Bolts, Nuts and Washers

Water Closet Screws, Bolts, Nuts and Washers (1)  Every screw, bolt, nut and washer shall be of materials that are resistant to corrosion, when used,     (a)   to connect a water closet to a floor flange,     (b)   to anchor the floor flange to the floor,     (c)   to anchor the water closet to the floor, […]
Read more

Water Distribution Systems

Water Distribution Systems (1)  Except as provided in Sentence (2), every water distribution system shall be connected,     (a)   to a watermain that is part of a municipal drinking water system, or     (b)   to a drinking water system, if a watermain described in Clause (a) is not available.     (2)  Storm sewage or greywater that is […]
Read more

Water Hammer Arresters

Water Hammer Arresters (1)  Factory built water hammer arresters shall conform to ANSI/ASSE 1010, “Water Hammer Arresters”. Article 7.2.10.15. Ontario Regulation 332/12 Building Code, Information published by oncodes.ca for educational purposes only Note: When water flow in a pipe system abruptly ceases due to fast-closing shutoff valves, dishwashers, and laundry washers, water hammer arrestors are employed to […]
Read more

Withstanding Pressure Plumbing Discharge

Withstanding Pressure Plumbing Discharge (1)  Piping, fittings and joints used in pressure sewer, forcemain or sump pump discharge applications shall be capable of withstanding at least one and one-half times the maximum potential pressure. Article 7.2.1.5 Ontario Regulation 332/12 Building Code,   Information published by oncodes.ca for educational purposes only.