Maximum Spans for Glued-Laminated Timber Lintels – 20f-E Stress Grade – Exterior Walls – Roof and Ceiling Load Only
Table A-16
Forming Part of Sentences 9.23.12.3.(1) and (3) and 9.37.3.1.(1)
Notes to Table A-16:
(1) Spans are valid for glued-laminated timber conforming to CAN/CSA-O122 and CSA O177.
(2) Provide a minimum bearing length of 89 mm. (Alternatively, the bearing length may be calculated in accordance with Part 4.)
(3) Top edge of lintel assumed to be fully laterally supported.
(4) Supported Length means half the length of trusses or rafters, plus the length of overhang beyond the wall.
(5) For intermediate supported lengths, straight interpolation may be used.
Table A-16 Ontario Regulation 332/12 Building Code, Information published by oncodes.ca for educational purposes only.